Reproducible data cleaning

Sensor & lab CSV cleaning + 2 publication-grade figures

Get a cleaned CSV, two figures in PNG and SVG, and a rule-by-rule audit trail you can trace back to the source.

$39 Fixed Price 24h Delivery 1 Free Revision

Before and after

Inspect both figures from the sample sensor CSV.

Transparent audit trail

Rule counts can overlap. The JSON log records the one-based source line for each counted occurrence.

Choose an audit view
Sample cleaning rules, counts and actions
RuleCountAction
metadata_comments3Skip lines starting with # outside a CSV record.
blank_lines1Skip blank lines outside a CSV record.
header_normalized1Trim and lowercase the header (count once if any name changes).
extra_columns_ignored0Ignore custom columns (count by column in the header).
wrong_column_count0Drop rows with a different field count than the header.
invalid_timestamp1Drop rows with a missing or unparseable timestamp.
timestamp_normalized137Write UTC ISO 8601 timestamps with Z; assume UTC when no offset is supplied.
duplicate_timestamp2Keep the row with the most valid readings at each UTC instant; break ties by first input row.
no_valid_measurements1Drop winning rows with both measurements missing or rejected.
reordered_rows126Sort retained rows by UTC timestamp; count rows whose positions change.
temperature_c_trimmed20Trim surrounding measurement whitespace.
temperature_c_unit_removed23Strip an optional unit suffix (°C, C) without conversion.
temperature_c_missing4Write blank for an empty field or a case-insensitive NA, N/A, NaN, null or none token.
temperature_c_invalid1Write blank for unparseable or non-finite measurements.
temperature_c_out_of_range2Write blank for readings outside [10, 45] (inclusive valid range).
voltage_v_trimmed17Trim surrounding measurement whitespace.
voltage_v_unit_removed20Strip an optional unit suffix (V) without conversion.
voltage_v_missing3Write blank for an empty field or a case-insensitive NA, N/A, NaN, null or none token.
voltage_v_invalid0Write blank for unparseable or non-finite measurements.
voltage_v_out_of_range2Write blank for readings outside [2.8, 3.6] (inclusive valid range).
{
  "raw_sha256": "07773456f3c6c2f56ef29566dff83eecfcee89e2239e4af77db3836752591ed1",
  "raw_rows": 183,
  "cleaned_rows": 179,
  "dropped_rows": 4,
  "rules": {
    "invalid_timestamp": {
      "description": "Drop rows with a missing or unparseable timestamp.",
      "count": 1,
      "source_lines": [
        107
      ]
    },
    "duplicate_timestamp": {
      "description": "Keep the row with the most valid readings at each UTC instant; break ties by first input row.",
      "count": 2,
      "source_lines": [
        32,
        59
      ]
    }
  }
}

Scope & boundaries

What’s included

  • One sensor or lab CSV, up to 100,000 rows and 15 columns.
  • Cleaned CSV with reproducible rules, a cleaning report, and a JSON audit log.
  • Two publication-grade figures, each in PNG and SVG, plus one free revision.

Out of scope

  • Files above the row or column limit and multi-file merges.
  • Data fabrication or filling missing readings with invented values.

Payment & how to order

  1. Send a 20-row sample

    Include the header, remove sensitive values, and describe the two figures you need.

  2. Confirm the fixed scope

    Agree on cleaning rules and figure requirements for $39.

  3. Pay & receive deliverables

    Delivery within 24 hours of payment.

Payment options

USDC or USDT. Standard payment available upon request.

Send your sample

Contact details are pending.